January/2019 Braindump2go 300-175 Exam Dumps with PDF and VCE New Updated Today! Following are some new 300-175 Real Exam Questions:

1.|2019 Latest 300-175 Exam Dumps (PDF & VCE) 353Q&As Download:

https://www.braindump2go.com/300-175.html

2.|2019 Latest 300-175 Exam Questions & Answers Download:

https://drive.google.com/drive/folders/0B75b5xYLjSSNZjVxdkhhREFxblU?usp=sharing

QUESTION 197
Which two statements are true concerning authorization when using RBAC in a Cisco Unified Computing System? (Choose two.)

A. A locale without any organizations, allows unrestricted access to system resources in all organizations.
B. When a user has both local and remote accounts, the roles defined in the remote user account override those in the local user account.
C. A role contains a set of privileges which define the operations that a user is allowed to take.
D. Customized roles can be configured on and downloaded from remote AAA servers.
E. The logical resources, pools and policies, are grouped into roles.

Answer: AC
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/1-4/UCSM_GUI_Configuration_Guide_1_4_chapter9.html
User roles contain one or more privileges that define the operations allowed for the user who is assigned the role.
One exception to this rule is a locale without any organizations, which gives unrestricted access to system resources in all organizations.

QUESTION 198
Which actions must be taken in order to connect a NetApp FCoE storage system to a Cisco UCS system?

A. Ensure that the Fibre Channel switching mode is set to Switching, and use the Fibre Channel ports on the Fabric Interconnects.
B. Ensure that the Fibre Channel switching mode is set to Switching, and reconfigure the port to a FCoE Storage port.
C. Ensure that the Fibre Channel switching mode is set to End-Host, and use the Ethernet ports on the Fabric interconnects.
D. Ensure that the Fibre Channel switching mode is set to Switching, and use the Ethernet ports on the Fabric Interconnects.

Answer: B
Explanation:
http://www.renar.net/?p=148&lang=en
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/release/notes/UCS_28313.html

QUESTION 199
Which two protocols are accepted by the Cisco UCS Manager XML API? (Choose two.)

A. SMASH
B. HTTPS
C. HTTP
D. XMTP
E. SNMP

Answer: BC
Explanation:
https://www.youtube.com/watch?v=INtEpEnXLUo – Communicates over HTTP/HTTPS
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/api/b_ucs_api_book/b_ucs_api_book_chapter_00.html
The API accepts XML documents through HTTP or HTTPS

QUESTION 200
An Cisco UCS Administrator is planning to complete a firmware upgrade using Auto install.
Which two options are prerequisites to run Auto Install? (Choose two.)

A. minor fault fixing
B. configuration backup
C. service profiles unmounted from the blade servers
D. time synchronization
E. fault suppression started on the blade servers

Answer: BD
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-2/b_GUI_Firmware_Management_22/b_GUI_Firmware_Management_22_chapter_0101.pdf

QUESTION 201
Which two prerequisites are required to configure a SAN boot from the FCoE storage of a Cisco UCS system? (Choose two.)

A. The Cisco UCS domain must be able to communicate with the SAN storage device that hosts the operating system image.
B. A boot policy must be created that contains a local disk, and the LVM must be configured correctly.
C. There must be iVR-enabled FCoE proxying between the Cisco UCS domain and the SAN storage device that hosts the operating system image.
D. There must be a boot target LUN on the device where the operating system image is located.
E. There must be a boot target RAID on the device where the operating system image is located.

Answer: AD
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-1/b_UCSM_GUI_Configuration_Guide_2_1/b_UCSM_GUI_Configuration_Guide_2_1_chapter_011111.pdf

QUESTION 202
You need to configure service profiles for a Cisco UCS system. What is an advantage of using the Export wizard to create the service profiles instead of using the Simple wizard?

A. Only the Expert wizard supports Fabric Interconnect expansion module ports to be used in 10-Gigabit uplink mode or Fibre Channel mode.
B. Both wizards support the same features, but the Expert wizard provides no configuration options for the features.
C. The Expert wizard supports stateless computing and mobile service profiles.
D. The Expert wizard supports all blade generations, whereas the Simple wizard supports only M1 blades, M2 blades, and Cisco VIC cards.

Answer: C
Explanation:
https://www.petri.com/cisco-ucs-creating-service-profile-templates
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html

QUESTION 203
You have a Cisco UCS system. You need to create VSAN 100 on a Cisco Nexus Series switch and to enable switch port fc 1/10 as a member for the VLAN.
Which command set should you use?

A. SITE-A-MDS-Fabric-A# vsan database
SITE-A-MDS-Fabric-A (vsan-db)# vsan 100 interface fc 1/10
SITE-A-MDS-Fabric-A (vsan-db)# vsan database commit
SITE-A-MDS-Fabric-A (vsan-db)# exit
B. SITE-A-MDS-Fabric-A# configure terminal
SITE-A-MDS-Fabric-A (config)# vsan database
SITE-A-MDS-Fabric-A (config-vsan-db)# vsan 100 interface fc 1/10
SITE-A-MDS-Fabric-A (config-vsan-db)# exit
C. SITE-A-MDS-Fabric-A# configure terminal
SITE-A-MDS-Fabric-A (config)# vsan database
SITE-A-MDS-Fabric-A (config-vsan-db)# vsan 100 interface fc 1/10
SITE-A-MDS-Fabric-A (config-vsan-db)# vsan database commit
D. SITE-A-MDS-Fabric-A# configure terminal
SITE-A-MDS-Fabric-A (config)# vsan database
SITE-A-MDS-Fabric-A (config-vsan-db)# vsan 100 interface fc 1/10
SITE-A-MDS-Fabric-A (config-vsan-db)# vsan database commit
SITE-A-MDS-Fabric-A (config-vsan-db)# exit

Answer: D
Explanation:
htps://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/sanos/quick/guide/qcg_vin.html

QUESTION 204
You need to implement a Cisco UCS system at a customer site.
Which adapters and operating systems have preprovisioned adapter policies?

A. Ethernet vNICs and Windows. OS X Server, and Oracle Solaris operating systems
B. Fibre Channel vNICs and Windows, FreeBSD, and Linux operating systems
C. Ethernet vNICs and Windows, VMware, and Linux operating systems
D. Fibre Channel vNICs and Windows, Oracle Solaris, and Linux operating systems

Answer: A
Explanation:
http://www.educationalcentre.co.uk/deploy-a-cisco-ucs-system-part-2-from-scratch-for-vmware-esxi/
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/b_UCSM_GUI_Configuration_Guide_2_2_chapter_010101.html#d71329e928a1635

Fibre Channel are not vNICs. They are vHBAs.
Ethernet are vNICs.
OSX Server is not a predefined policy.

QUESTION 205
You need to automate the management of servers, networks, and storage on a Cisco UCS system, by using PowerShell. Which tool should you use?

A. Cisco UCS Platform Emulator
B. Cisco UCS Python SDK
C. Cisco UCS Automation Tool
D. Cisco UCS PowerTool Suite

Answer: D
Explanation:
http://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/microsoft-applications-on-ucs/brochure_c02-705764.html

QUESTION 206
Which two Cisco UCS firmware are contained in the Cisco UCS Infrastructure software bundle? (Choose two.)

A. Cisco I/O module firmware
B. Cisco IMC
C. Cisco UCS BIOS
D. Cisco UCS fabric interconnects firmware
E. Cisco UCS adapters

Answer: AD
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Firmware-Mgmt/3-1/b_UCSM_GUI_Firmware_Management_Guide_3_1/b_UCSM_GUI_Firmware_Management_Guide_3_1_chapter_01.html
“A” BUNDLE
Infrastructure software bundle—This bundle is also called the A bundle. It contains the firmware images that the fabric interconnects, IO Modules, and Cisco UCS Manager require to function.
“B” BUNDLE
B-Series server software bundle—Also called the B bundle, this bundle contains the firmware images that the B-Series blade servers require to function, such as adapter, BIOS, CIMC, and board controller firmware. Release Bundle Contents for Cisco UCS Manager, Release 3.1 provides details about the contents of the B-Series server software bundle.

QUESTION 207
A server discovery policy is defined in Cisco UCS Manager.
Which two actions are initiated by the policy when a new server starts?

A. The qualification in the server discovery policy is executed against the server.
B. The scrub policy s applied to the server, if configured.
C. A service profile iis created for the server with the identity burned into the server at time of manufacture.
D. The inventory of the server is analyzed.
E. The server is assigned to the selected organization, if configured.

Answer: AD


!!!RECOMMEND!!!

1.|2019 Latest 300-175 Exam Dumps (PDF & VCE) 353Q&As Download:

https://www.braindump2go.com/300-175.html

2.|2019 Latest 300-175 Study Guide Video:

https://youtu.be/FC4JaHewCP8